It is recommended that the vent system has been installed
before hood is installed.
Before making cutouts, make sure there is proper
clearance within the ceiling or wall for exhaust vent.
Check your ceiling height and the hood height
maximum before you select your hood.
1. Disconnect power.
2. Determine which venting method to use: roof, wall,
or non-vented.
3. Select a flat surface for assembling the range hood.
Place covering over that surface.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
4. Using 2 or more people, lift range hood onto
covered surface.
5. Remove wood base from range hood and dispose
of properly.
Range Hood Mounting Screws Installation
1. Determine and mark the centerline on the wall where
the canopy hood will be installed.
2. Select a mounting height between a minimum of 24" (61 cm)
for an electric cooking surface, a minimum of 27" (68.6 cm)
for a gas cooking surface, and a suggested maximum of 36"
(91.4 cm) above the range to the bottom of the hood. Mark a
reference line on the wall.
3. Tape template in place, aligning the template centerline
and bottom of template with hood bottom line and with
the centerline marked on the wall.
D
R
L I
L
2
T (
W
O
)
3
1 /
6
"
P
L I
O
T
H
o
i r
o z
n
a t
l
L
n i
e
A. Centerline
B. Fastener locations
C. Mounting height reference (hood bottom line)
4. Mark centers of the fastener locations through the template
to the wall.
IMPORTANT: All canopy mounting screws must be installed
into wood where possible. If there is no wood to screw into,
additional wall framing supports may be required or use
the (4) 10 x 60 mm wall anchors and 5.4 x 75 mm screws.
Remove the template.

INSTALLATION INSTRUCTIONS

Prepare Location

A
H
O
L
E
S
T
H
R
O
U
G
H
S
T
U
D
S
O
R
R
E
A
R
W
A
L
L
S
U
P
P
O
R
T
R
E
A
R
W
A
L
L
M
O
U
N
T
N I
G
T
E
M
P
L
A
T
E
C
L
A
L
G I
N
B
O
T
T
O
M
E
D
G
E
W
T I
H
P
E
N
C
L I
L
N I
E
N I
D
C I
A
T
N I
G
B
O
T
T
O
M
O
F
T
H
E
H
O
O
D
n I
a t
s
l
a l
t
o i
n
H
e
g i
h
t
C
B
5. For wood, drill
/
" (4.8 mm) pilot holes at all locations
3
16
where screws are being installed into wood.
For wall anchors, drill
/
7
where wall anchors are being used.
6. For wood, install (2) 5 x 45 mm mounting screws. Leave
/
" (6.4 mm) gap between the wall and the back of the
1
4
screw head to slide range hood into place.
For wall anchors, install the 10 x 60 mm wall anchors
and install the 5.4 x 75 mm screws into the wall anchors.
Tighten until the wall anchors are secure. Back the screws
out
/
" (6.4 mm).
1
4
¹⁄₄"
(6.4 mm)
Vent Cover Support Bracket Installation
Installations using telescoping upper and lower vent
cover assembly
1. Position the vent cover bracket on wall about
away from the ceiling.
2. Mark the hole locations.
3. Drill (2)
/
" (9.5 mm) holes for 8 x 40 mm wall anchors
3
8
and insert anchors flush with the wall.
A
B
A. 8 x 40 mm wall anchors
B. Centerline on wall
C. Vent cover support bracket
D. 5 x 45 mm screws
4. Attach the vent cover support bracket to wall.
Complete Preparation
1. Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the
hood. See "Venting Requirements" section.
2. Determine the required height for the home power supply
cable and drill a 1
/
" (3.2 cm) hole at this location.
1
4
3. Run the home power supply cable according to the National
Electrical Code or CSA Standards and local codes and
ordinances. There must be enough
from the fused disconnect (or circuit breaker) box to make
the connection in the hood's electrical terminal box.
NOTE: Do not reconnect power until installation is complete.
4. Use caulk to seal all openings.
" (10 mm) holes at all locations
16
/
" (3 mm)
1
8
C
D
/
" conduit and wires
1
2
7