Whirlpool UXT4830AA Informations sur l'installation

Parcourez en ligne ou téléchargez le pdf Informations sur l'installation pour {nom_de_la_catégorie} Whirlpool UXT4830AA. Whirlpool UXT4830AA 1 pages. Whirlpool range hood specification sheet

Range Hood - 30" (76.2 cm) and 36" (91.4 cm)
PRODUCT MODEL NUMBERS
UXT4830AA
UXT4836AA
Electrical: A 120 Volt, 60 Hz., AC only, 15-amp, fused
electrical circuit is required.
CABINET OPENING DIMENSIONS
30" (76.2 cm) or
36" (91.4 cm) min.
cabinet opening width
18"(45.7 cm) min.
24" (61.0 cm)
suggested max.
bottom of cabinet
to cooking surface
18" (45.7 cm)
min. clearance
upper cabinet
to countertop
36" (91.4 cm)
base cabinet
height
x 10" (8.3 x 25.4 cm) vent system
x 10"
(8.3 x 25.4 cm)
elbow
6 ft. ( 1.8 m)
Maximum length
1 - 90° elbow
8 ft. (2.4 m) straight
1 - wall cap
2 ft.
(0.6 m)
Length of
10" (8.3 x 25.4 cm) system
NOTE: Flexible vent is not recommended
x 10" (8.3 x 25.4 cm) vent system
x 10"
x 10"
(8.3 x 25.4 cm)
(8.3 x 25.4 cm)
flat elbow =
90° elbow =
12 ft. (3.7 m)
5 ft. (1.5 m)
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
13" (33.0 cm)
cabinet depth
wall cap
= 35 ft.
(10.7 m)
= 5 ft.
(1.5 m)
= 8 ft.
(2.4 m)
= 0 ft.
(0 m)
x
= 13 ft.
(3.9 m)
x 10"
(8.3 x 25.4 cm)
wall cap =
0 ft. (0 m)
OVERALL DIMENSIONS
12"
(30.5 cm)
9"
(22.9 cm)
(5.1 cm)
6"
(15.2 cm)
"
(1.9 cm)
29 " (75.9 cm) - 30" (76.2 cm) model
35 " (91.1 cm) - 36" (91.4 cm) model
VENTING REQUIREMENTS
Roof Venting
A
B
C
A. 7" (17.8 cm) round vent or a
3 " x 10" (8.3 x 25.4 cm) vent
through roof
B. Round vent: use 7" (17.8 cm)
round damper
(purchased separately)
C. 18" (45.7 cm) - 24" (61.0 cm)
above cooking surface
D. Roof cap
90˚ elbow
2 ft
(0.6 m)
7" (17.8 cm) vent system
90° elbow =
45° elbow =
5 ft. (1.5 m)
2.5 ft. (0.8 m)
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
1 "
(3.8 cm)
1"
(2.5 cm)
2"
1 "
(3.8 cm)
"
7 "
(9.5 mm)
(19.1 cm)
Wall Venting
D
A
B
C
A. 7" (17.8 cm) round vent or a
3 " x 10" (8.3 x 25.4 cm) vent
through the wall
B. 3 " x 10" (8.3 x 25.4 cm)
through the wall
C. 18" (45.7 cm) - 24" (61.0 cm)
above cooking surface
D. Wall cap
7" (17.8 cm) vent system
Wall cap
6 ft (1.8 m)
Maximum length
1 - 90° elbows
8 ft. (2.4 m) straight
1 - wall cap
Length of 7"
(17.8 cm) system
NOTE: Flexible vent is not recommended
x 10"
7" (17.8 cm)
(8.3 x 25.4 cm) to
wall cap =
7" (17.8 cm) =
0 ft. (0 m)
4.5 ft. (1.4 m)
17 "
(44.5 cm)
D
= 35 ft.
(10.7 m)
= 5 ft.
(1.5 m)
= 8 ft.
(2.4 m)
= 0 ft.
(0 m)
= 13 ft.
(3.9 m)
x 10"
(8.3 x 25.4 cm)
to 7" (17.8 cm)
90° elbow =
5 ft. (1.5 m)
Ref. W10240580A
07-30-09