Whirlpool WVW51UC6LS Instructions d'installation et manuel d'utilisation et d'entretien - Page 4
Parcourez en ligne ou téléchargez le pdf Instructions d'installation et manuel d'utilisation et d'entretien pour {nom_de_la_catégorie} Whirlpool WVW51UC6LS. Whirlpool WVW51UC6LS 28 pages. 30" and 36" (76.2 and 91.4 cm) wall-mount canopy
Tools and Parts
Gather the required tools and parts before starting
installation. Read and follow the instructions provided
with any tools listed here.
Tools Needed
■
Level
■
Drill with 1
/
" (3.2 cm),
1
4
and
/
" (7.9 mm) drill bits
5
16
■
Pencil
■
Wire stripper or utility knife
■
Tape measure or ruler
■
Pliers
■
Caulking gun and weatherproof caulking compound
■
Vent clamps
■
Jigsaw or keyhole saw
■
Flat-blade screwdriver
■
Metal snips
■
Phillips screwdriver
■
T20
Torx
adapter
®
®†
Parts Needed
■
Home power supply cable
■
/
" (12.7 mm) UL listed or CSA approved strain relief
1
2
■
3 UL listed wire connectors
For Vented Installations, You Will Also Need:
■
1 wall or roof cap
■
Metal vent system
For Non-Vented (Recirculating) Installations,
You Will Also Need:
■
Recirculation Kit for non-vented (recirculating) installations
only. See the "Assistance or Service" section to order.
■
6" (15.2 cm) diameter round metal vent duct -
length required is determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
■
Hood canopy assembly with blower, LED lights and
canopy glass already installed
■
Vent transition with back draft dampers installed
■
Vent cover support bracket
■
Metal grease filter
■
Mounting template
■
2-piece vent cover
■
2 - 3.5 x 9.5 mm mounting screws (Phillips)
■
4 - 4 x 8 mm screws (T20
■
6 - 5 x 45 mm mounting screws (#2 Phillips)
■
4 - 8 x 40 mm wall anchors
†
TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
®
4
INSTALLATION REQUIREMENTS
/
" (3.2 mm),
1
8
drive)
®†
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/
rating plate is located behind the left filter on the rear wall
of the vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors, and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
This range hood is recommended for use with cooktops with
a maximum total rating of
65,000
Grounded electrical outlet is required. See the "Electrical
Requirements" section.
The canopy hood is factory set for venting through the roof
or wall. For non-vented (recirculating) installation, see "For
non-vented (recirculating) installation only" in the "Connect
Vent System" section. Recirculation Kit is available from your
dealer or an authorized parts distributor. See the "Assistance or
Service" section to order.
All openings in ceiling and wall where canopy hood will be
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280)
or, when such standard is not applicable, the standard for
Manufactured Home Installation 1982 (Manufactured Home
Sites, Communities and Setups) ANSI A225.1/NFPA 501A,
or latest edition, or with local codes.
Product Dimensions
10
/
"(27.5 cm)
13
16
17
/
"(45 cm)
11
16
BTUs or less.
30"(76.2 cm) or
36" (91.4cm)