C O D E RE Q U I RE M E N TS
It is the responsibility of the user to consult with the local municipality and to
installation and operation of the fire feature.
M I N I M U M AN D MAXI M U M GAS I N L E T P RE S S U RE S
Your FIRESTORM has been provided with a LP hose with an in-line regulator set at 11" W.C. (2.7399 Kpa). Any additional fuel lines or
regulators must be provided by Live Outdoor or a qualfied gas professional within the specified minimum and maximum gas inlet
pressures below:
LO CAT I O N C O N S I D E RAT I O N S
The FIRESTORM is designed and intended for outdoor use only.
Select a location where the appliance can be attended during operation. Never leave an operating appliance unattended or
by someone not familiar with its operation or shutoff procedure.
Pick a location that allows sufficient horizontal room to enjoy the appliance while allowing a safe distance from the heat and flame.
Keep the area around the appliance clear of combustible materials, gasoline, and other flammable substances. Do not burn
solid fuels in this appliance.
Choose a location that allows easy access to the fire feature.
Appliances may create very high temperatures - combustibles must be located far enough away that there is no risk of
ignition.
C L EARAN C E RE Q U I RE M E N TS
Your FIRESTORM must only be used in a location that provides sufficient clearance from combustible materials. Never use
your FIRESTORM on a combustible surface and provide side and top clearance as follows:
36" side clearance from any combustible structure or materials.
Overhead clearance should be a minimum 72" from the top of the appliance to combustible structures or materials.
Always consult with local municipality regarding any local code requirements.
The FIRESTORM must be placed on a stable surface and must be level.
M E D IA
Media is not required but may be used on the FIRESTORM.
Only use approved decorative media (lava rock, ceramic log sets, etc.) that have been manufactured for specific use in fire
features.
Do not use fire glass as it, or debris from it, may fall into the burner pan.
Media must be ½" or larger in size to prevent media from falling into gas orifices and blocking flow of gas out of jets. Use
approved media only. To avoid dust and clogs getting into the system, do not dump the media over the burner. Place the
media onto the plate or pan.
Burner may be covered by approved media up to 1/2" above the jets. Media may also be positioned so that jet tips or barrels
are visible. Covering jets by more than 1/2" of media may create back pressure and gas leakage resulting in pooling of gas
under the fire feature which can result in explosion which could cause property damage, personal injury, or death.
GAS INLET PRESSURES
MATCH LIT
Minimum
Liquid Propane
11.0" W.C.
(2.7399 Kpa)
www.GoLiveOutdoor.com | (720) 679-9800 | [email protected]
FOLLOW ALL LOCAL CODES
Maximum
13.0" W.C.
(3.2381 Kpa)