Main structure in AISI 430 with 4 adjustable height feet.
−
Panels in stainless steel AISI 304, thickness 10-12/10.
−
Cooking vat in stainless steel AISI 316, thickness 20/10 ÷ 40/10.
−
Chrome-plated brass drainage tap.
−
The temperature limiting device which switches off automatically the appliance in case of overheating of
cooking-vat-bottom.
−
Stainless steel lid with heat-resistant silicone gasket.
−
Hermetic closing of lid ensured by 4 screw clamps.
−
The relief valve for the pressure that develops inside the cooking vat is set at 0,05 bar.
−
On request, the appliance can be equipped with a pressure gauge indicating the pressure inside the
cooking vat.
1.4. LAWS, TECHNICAL PRESCRIPTIONS AND DIRECTIVES
When installing the appliance it is necessary to follow and comply with the following regulations:
−
current regulations on the matter;
−
any hygienic-sanitary regulations concerning cooking environments;
−
municipal and/or territorial building regulations and fire prevention prescriptions;
−
current accident prevention guidelines;
−
electricity board regulations concerning safety;
−
the regulations of the electrical power supply company or agency;
−
any other local prescriptions.
1.5. SPECIAL REQUIREMENTS FOR THE INSTALLATION SITE
−
The room in which the appliance is to operate must be well ventilated.
−
In addition, it is good policy to locate the appliance under an extractor hood so that cooking vapours can
be removed rapidly and continuously.
−
Current regulations require the installation of a multiple pole switch between the appliance and the
electrical power supply; the switch must have a contact gap of least 3 mm on each pole.
−
This appliance requires two water connections: one for hot and one for cold water. Each line must be
fitted with an on-off valve.
Warning! :
The electrical isolating switch and the water shutoff valves must both be located near
to the appliance, within easy reach for the user.