ErgoAV ERMCM1-01B Manuel d'instruction - Page 11
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} ErgoAV ERMCM1-01B. ErgoAV ERMCM1-01B 20 pages. Ceiling tv mount
3A-3
3A-4
Step 3B Solid Concrete Ceiling Option
WARNING:
●
To avoid personal injury or property damage, Do Not over-tighten the Lag
Screws [A1]. Using a self-supplied Socket Wrench, tighten the Lag Screws [A1]
only until they are pulled firmly against the Ceiling Plate and ceiling.
● Ensure the Ceiling Plate is securely fastened to the ceiling
before continuing to the next step.
● Mount the Ceiling Plate [02] directly onto the concrete
surface without any covering.
● The thickness of the ceiling must exceed 5 1/2" (140mm).
● Do not use a drill for tightening the lag screws! Only use a socket wrench.
Electric Drill
(NOT Included)
CAUTION:
DO NOT drill the holes at the
edge of the ceiling joist. Make
sure the holes are drilled on the
center location of the ceiling joist.
Drill 4 pilot holes using a 7/32"
(5.5mm) diameter drill bit. Make
sure the depth of the pilot holes
is at least 2 3/4" (70mm) deep.
CAUTION: DO NOT use a drill to
tighten the Lag Screws. Only use
a Socket Wrench.
Install the Ceiling Plate [02] using
Lag Screws [A1]. Tighten the Lag
Screws [A1] only until they are
pulled firmly against the Ceiling
Plate. DO NOT over-tighten the
Lag Screws.
11
2 3/4" (70mm)
7/32" (5.5mm)
1/2" (13mm)
Socket Wrench
(NOT Included)
Anchor
A2