230611-20 ALT4
Disposal of Ashes
Ashes should be placed in a metal container with a tight fi tting lid. The closed container of
ashes should be placed outside on a non-combustible fl oor or on the ground, well away
from all combustible materials, pending fi nal disposal. If the ashes are disposed of by burial
in soil or otherwise locally dispersed, they should be retained in a closed container until all
cinders have thoroughly cooled. Other waste should not be placed in this container.
Baffle Removal
Chimney connector pipe should be disconnected from stove to clean and inspect.
Only if this is not possible should you remove baffle assembly.
DO NOT OPERATE WITH BAFFLE ASSEMBLY OR INSULATION REMOVED.
Removal
Remove retaining pin located at the rear top of the fi rebox, just below the
baffle. Remove rail extensions in front of Baffle. Lift baffle up and pull forward to
disconnect from the supply tube. Tilt baffle sideways to drop down and remove
from fi rebox. Inspect gasket between baffle and supply tube. If necessary, replace
with gasket #139.5 available from your Pacifi c Energy dealer. Re-install baffle as-
sembly in reverse order. The two side pieces of insulation must be tight against
the siderails.
Optional Blower
The optional blower kit (kit #WODC.BLOW) is equipped with a three prong power
cord and may be installed at any time. Follow installation instructions supplied with
the kit. Route power supply cord away from heater.
Electrical rating: 115 volts A.C.- 0.84 amps.
Fan output rating: 125 CFM
Blower Operation
Proper blower speed matched with air control setting will ensure peak performance
from your stove. Operate as follows:
• Air control set to low (right position), operate blower speed control on "Low".
• Air control set between low and high (middle position), operate blower
speed control at desired setting.
Automatic: To operate the blower automatically, set the rocker switch on the
side of the fan housing to "Auto" and set the speed control to desired setting. This
will allow the fan to turn on as the stove heats up to operating temperature. It will
also shut the blower off after the fi re has gone out and the unit cooled to below a
useful heat output range.
Manual: To manually operate the blower, set the rocker switch to "Man" and set
the speed control to desired setting. This will bypass the sensing device and allow
full control of the blower.
Switching from "Auto" to "Man" or selecting speed may be done anytime.