Alderlea T5 Manuel d'installation et d'utilisation - Page 19

Parcourez en ligne ou téléchargez le pdf Manuel d'installation et d'utilisation pour {nom_de_la_catégorie} Alderlea T5. Alderlea T5 20 pages.

Label

CERTIFIED FOR CANADA AND U.S.A.
LISTED ROOM HEATER, SOLID FUEL TYPE.
ALSO FOR USE IN MOBILE HOMES
TESTED TO CAN/ULC S627-M93 AND UL 1482-98
MODEL SERIES D:
WN# 16408
• INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND INSPECTION IN
YOUR AREA.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE (USA. ONLY).
• USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR.
• CONNECT TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS.
• DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER.
• SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING
A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.
• DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING.
• MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS-
18INCHES/455MM. CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR
OTHER MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
RESIDENTIAL INSTALLATION
USING SINGLE WALL CONNECTOR
VERTICAL CONNECTOR
A. SIDEWALL TO UNIT
18 in. / 455 mm
B. BACKWALL TO UNIT
12 in. / 305 mm
C. CORNER TO UNIT
11 in. / 280 mm
D. SIDEWALL TO CONNECTOR
27 in. / 685 mm
E. BACKWALL TO CONNECTOR 19 in. / 485 mm
F. CORNER TO CONNECTOR
22 in. / 560 mm
HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES
AS TESTED - PIPE SHIELD MAY BE REQUIRED BY LOCAL AUTHORITIES.
* COMBUSTIBLE ALCOVE SIZE : DEPTH - 4 FT. / 1.22 M MAXIMUM, HEIGHT 7 1/2 FT. / 2.3 M MINIMUM
COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL EXTENDED TO THE
FRONT, SIDES AND BACK AS INDICATED.
IN CANADA
G.
18 INCHES / 455 MM
H.
8 INCHES / 200 MM
I.
8 INCHES / 200 MM
IN U.S.A.
G.
16 INCHES / 405 MM
H.
5 INCHES / 127 MM
I.
0 INCHES / 0 MM
COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION: OUTSIDE AIR KIT, AND ONE OF THE
FOLLOWING LISTED CONNECTORS: SECURITY MODELS DP OR DC, OLIVER MACLEOD MODEL PV, ENERGY VENT
E VENT, SELKIRK METALBESTOS MODEL DS, METAL FAB MODEL DW, AMERI-TEC MODEL DBSP, INDUSTRIAL
CHIMNEY MODEL EXCEL ULTRA-BLACK, OR SIMPSON DURA-VENT MODEL DVL IN COMBINATION WITH ONE OF THE
FOLLOWING COMPATIBLE CHIMNEY SYSTEMS: APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT
ATTACHED.BOTH CHIMNEY SYSTEM AND CONNECTOR MUST BE LISTED TO:
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
IN CANADA - ULC S-641 LISTED CONNECTOR AND ULC-S-629 LISTED CHIMNEY
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
IN USA - UL-103 HT LISTED CONNECTOR AND CHIMNEY
USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
OPTIONAL COMPONENTS - WATER COIL (CANADA ONLY), FAN KIT #SSER.BLOW, FAN ELECTRICAL RATING: 115V,
60HZ, 80WATTS. DO NOT ROUTE POWER CORD BENEATH HEATER.
CAUTION: RISK OF EXCESSIVE TEMPERATURES - KEEP ASH DUMP CLOSED DURING FIRING OF THE HEATER.
OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.
REPLACE GLASS ONLY WITH CERAMIC GLASS.
HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN
BURNS. SEE NAMEPLATE AND INSTRUCTIONS.
U.S. ENVIRONMENTAL PROTECTION AGENCY
CERTIFIED TO COMPLY WITH
JULY, 1990, PARTICULATE EMISSION
STANDARDS
280312
5050.75
020512-20 ALT5
SUPER 27
SPECTRUM
RESIDENTIAL CLOSE CLEARANCE
INSTALLATION
USING DOUBLE WALL CONNECTOR
HORIZONTAL CONNECTOR VERTICAL CONNECTOR HORIZONTAL CONNECTOR
14 in. / 355 mm
14 in. / 355 mm
14 in. / 405 mm
8 in. / 200 mm
5 in. / 127 mm
5 in. / 127 mm
11 in. / 280 mm
4 in. / 102 mm
4 in. / 102 mm
23 in. / 585 mm
22.5 in. / 570 mm 22.5 in. / 570 mm 24.5 in. / 620 mm 24.5 in. / 620 mm
15 in. / 380 mm
11.5 in. / 292 mm 11.5 in. / 292 mm 16.5 in. / 420 mm 14.5 in. / 370 mm
22 in. / 560 mm
14.5 in. / 370 mm 14.5 in. / 370 mm
BACK WALL
BACK I
B
H
H
A
HEATER
D
G
FRONT
CAUTION
DATE OF MANUFACTURE
J
F
M
A
2009
2010
MADE IN CANADA
DO NOT REMOVE THIS LABEL
WH-
ALDERLEA T5
CLASSIC
* ALCOVE
MOBILE HOME
INSTALLATION
INSTALLATION
USING
USING
DOUBLE WALL
DOUBLE WALL
CONNECTOR
CONNECTOR
16 in. / 405 mm
16 in. / 405 mm
10 in. / 255 mm
8 in. / 200 mm
N/A
8 in. / 200 mm
N/A 18.5 in. / 470 mm
ADJACENT WALL
C
E
F
MANUFACTURED BY:
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
M J
J
A S O N D
2011
2012
2013 2014
SUP1-A2
19
REAR VIEW
LABEL LOCATION