eControls Comfort 365 C365T11 Manuel de l'installateur - Page 3
Parcourez en ligne ou téléchargez le pdf Manuel de l'installateur pour {nom_de_la_catégorie} eControls Comfort 365 C365T11. eControls Comfort 365 C365T11 8 pages.
WIRING DIAGRAM
Model R80CT-XX
Downstairs Damper
HVAC System
G
Y
W
C
R
Model C365T11
Downstairs Thermostat
R
C
W
Y
G
Upstairs
Sensor
C365T11
Model TS5
Upstairs
Temperature
Sensor
Model R80CT-XX
Upstairs Damper
Model A80-MOC
Damper Actuator
CLS
Modulating or
OPN
Open/Close
COM
24VAC,2.4VA
Made in USA
eControls, Inc.
Model A80-MOC
Damper Actuator
CLS
Modulating or
OPN
Open/Close
COM
24VAC,2.4VA
Made in USA
eControls, Inc.
COM
CLS
OPN
COM
CLS
OPN
Upstairs
Sensor
WIRING INSTRUCTIONS
Warning!
Turn the power to the HVAC equipment off before wiring.
Equipment Wiring
Use 5-conductor, 18 or 20 gage, thermostat cable to wire from
the C365 Thermostat to the equipment.
C365
Wire Color
Terminal
R
Red
C
Blue
W
White
Y
Yellow
G
Green
Damper Wiring
Use 3-conductor, 18 or 20 gage, thermostat cable to wire from
the C365 Thermostat to the upstairs and downstairs dampers.
There are separate terminals for the upstairs and the
downstairs dampers.
C365
Wire Color
Terminal
COM
White
CLS
Red
OPN
Green
Multiple dampers can be used to construct the upstairs or
downstairs zones. Daisy chain terminals– COM to COM, OPN
to OPN and CLS to CLS.
Upstairs Temperature Sensor Wiring
Use 2-conductor, 18 or 20 gage, thermostat cable to wire from
the C365 Thermostat to the upstairs temperature sensor.
C365
Wire Color
Terminal
SNR
White
SNR
Red
For single temperature sensor application, use Model TS5-10.
Two temperature sensors can be installed in different areas
upstairs and the two temperatures will be averaged. For dual
sensor applications, use Model TS5-20 and daisy chain the
sensors.
3
Equipment
Function
Terminal
R, Rc, Rh
24VAC Power
C
Common
W, W1
Heating
Y, Y1
Cooling
G
Fan
Damper
Function
Terminal
COM
Common
CLS
Closes damper
OPN
Opens damper
Sensor
Function
Terminal
SNR
Thermistor
SNR
Thermistor