Clark Synthesis TST429 Manuel d'installation - Page 7

Parcourez en ligne ou téléchargez le pdf Manuel d'installation pour {nom_de_la_catégorie} Clark Synthesis TST429. Clark Synthesis TST429 20 pages. Platinum, gold, silver and all weather transducers
Également pour Clark Synthesis TST429 : Manuel complémentaire (4 pages), Manuel d'installation (8 pages), Manuel d'installation (1 pages), Manuel de l'acheteur (2 pages), Manuel d'installation (20 pages), Spécifications (1 pages)

Clark Synthesis TST429 Manuel d'installation
Installation Type: T-Nut
Requires initial access to the top of the material to
insert the T-nut, which installs flush to the surface.
(Drill a 7/16" hole for the T-nut).
Minimum 3-1/2" vertical space required, including
1/2" clearance between the Transducer and the
T-Nut
3/4"-thick
mounting
surface
Flat Washer
Lock Washer
Transducer Lead Wire
www.clarksynthesis.com
floor.
Drill 7/16" hole
Jam Nut (up)
3/8"-16
Threaded Stud
Jam Nut (down)
Washers
Jam Nuts
Installation: Overview
Installation Type: Hex Bolt
For use with metal, plastic, or other mounting surfaces
no thicker than 1/4". Requires access to the top of
the mounting surface both to install the bolt and to
tighten it.
Minimum 3-1/4" vertical space required, including
1/2" clearance between the Transducer and the
Maximum
1/4"-thick mounting
NEVER TIGHTEN
surface
BY TURNING THE
Transducer. MAKE
SURE TO TIGHTEN
THE JAM NUT
AGAINST THE
Transducer'S BRASS
NUT
floor.
3/8"-16
Hex Bolt
Flat Washer
Lock Washer
Jam Nut (up)
Jam Nut (down)
Transducer Lead Wire
Flat Washer
Lock Washer
Jam Nuts
Tactile Sound Transducers
Drill 7/16" hole