Installation Instructions
Switch setting
Switches should preferably be set BEFORE mounting on signal head. Access to the
switches is gained by removing the appropriate weatherproof plug, see Photograph 2.
Ensure that the plugs are replaced and securely tightened after setting the switches.
Photograph 2 -
Rear View of Detector
Access to Range Switch
Range selection
Unless otherwise ordered detectors are normally supplied with the range set to 35m
(position 3), this is the recommended setting for most applications. Other settings are
available between 20m and 60m, as shown in Table 1. These may be selected according
to local traffic engineering requirements. For example, a shorter range may be selected to
prevent actuations from traffic on a roundabout a short distance away. It is important to
select the correct range. This detector is a true range-finding RADAR, where range is
determined by electronic processing. It CANNOT be adjusted by changing the tilt angle
(see Mounting below).
S00104101MVDHandbook.doc
July 2002
Position
Range (m)
0
20
1
25
2
30
3
35
4
40
5
45
6
50
7
60
Table 1 - Range setting
Access to Mode Switch