Jerguson
360 Series
Rebuild Kit Disassembly
1. Remove handle from valve by taking off the the acorn nut, lock washer, and spacer. Secure valve
into a vice with the large compression nut facing upward. Take care not to damage any of the
external components. Remove anti rotation pin and discard. Use large wrench to remove the
compression nut
Acorn Nut
2. Remove the inlet gland, and inlet gland spiral wound gasket.
3. Remove Disc Spring, and Downstream Seat.
16633 Foltz Parkway ● Strongsville, OH 44149 USA ● Telephone: +1 (440) 572-1500 ● Fax: +1 (440) 238-8828
Spacer
Lock Washer
Inlet Gland
Spiral Wound Gasket
www.Jerguson.com ● [email protected]
Anti-Rotation Pin
Disc Spring
7
IOM J500.36
2017.10
Downstream Seat