Platform: DBALL2
Firmware: NISS08EU
LED Diagnostics & Troubleshooting
LED
Status
Module Progra mming
Off
Off
Solid red
Solid
Solid green for
Solid
green
3 seconds
x3 sec
Ex terna l Module Synchronisa tion
Flashes red,
red, then
Flashes
orange x 10
red, red,
orange
Active Ground W hile Running
Flashes green
Flashes
green
Flashes red &
orange
Flashes red
& orange
Flashes green
Flashes
quickly
green
D2D a nd W 2W Comma nds
Flashes orange
Flashes
orange
x1
x 1
Flashes orange
Flashes
orange
x2
x 2
Flashes orange
Flashes
orange
x 3
x3
Description
Module has no power.
W aiting to begin the
programming sequence.
Module was successfully
programmed.
OBDII feature not supported.
GROUND OUT ON (GW R)
command received.
IGNITION ON command received.
START ON command received.
LOCK command received.
UNLOCK command received.
TRUNK command received.
Troubleshooting
Check the power connections.
Make sure that the CAN connections are correct and
press PTS to turn ignition ON.
Normal operation
Diagnostic data bus not detected. Some features are
not supported by SmartStart. This can be caused by
missing wire connections or module hardware limitation.
Refer to the wiring installation section to check the
connections.
Otherwise, the Ground W hile Running (status) signal
was lost or was never received by the module.
Commands can come from RF, D2D or W 2W .
Otherwise, the ignition signal was not received by the
module. In a W 2W install, it will show only if the ignition
input wire is used.
Otherwise, the start signal was not received by the
module. In a W 2W install, it will show only if the ignition
input wire is used.
If the bypass module fails to flash, it means the module
did not receive the signal. Commands can come from
RF, D2D or W 2W .
Rev.: 20200502
Page 9