TROUBLESHOOTING

SYMPTOM
Tool runs at normal
speed but slows down
under any load.
Tool runs slowly. Air flows
weakly from exhaust.
Tool will not run. Air flows
freely from exhaust.
Tool will not shut off.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
PROBLEM
1. Motor parts worn.
2. Worn or sticking
mechanism due to
lack of lubricant.
1. Motor parts jammed
with gum/dirt.
2. Air-line regulator in
closed position.
3. General airflow
blocked by dirt.
1. Motor vanes stuck
due to buildup of
foreign material.
1. Throttle O-rings
damaged or ill-fitting
in seat.
11
SOLUTION
1. Return to Clarke dealer
for repair.
2. Drip air tool lubricating
oil into air inlet. Allow oil
to soak moving parts
before using.
1. Examine inlet air filter for
blockage. Drip a few
drops of air tool lubricat-
ing oil into air inlet.
2. Adjust in-line regulator to
open position.
3. Operate tool in short
bursts.
1. Disconnect air supply
and rotate tool assembly
manually.
2. Try operating tool in
short bursts.
3. Tap motor housing gently
with a rubber mallet.
4. Drip a few drops of air
tool lubricating oil into air
inlet to soak moving
parts.
1. Return to Clarke dealer
for repair.