HOW TO SELECT PRE-SET TORQUE SETTING
1. With the wrench in either peak or track mode, and the unit of
measurement already chosen, press the
value is displayed with the first digit flashing.
+
2. Press the
value is reached.
3. Press
button.
• The target torque will display for 3 seconds, then revert to 0.00.
M/u
4. Press
to set the value.
5. Press and hold the
• Again this will display for 3 seconds then revert to 0.00.
OPERATION
1. Place the square drive on to the socket or extension bar, perpendicular to
the nut/bolt to be tightened. Smoothly tighten your fastening, applying an
even pressure throughout the operation.
• As the target torque setting is approached, the LED will flash and the
alarm will bleep, before a continuous tone and light when the target
torque is reached or exceeded.
• If in PEAK mode, the red LED will light up and the alarm will bleep when
the target torque is reached and the highest measured reading will be
displayed and stored. Press the
another measurement.
CARE OF THE WRENCH DURING USE
1. Take care not to drop the wrench on a hard surface and re-set the unit as
described under MAINTENANCE & CALIBRATION, should it be subjected to
sudden shock.
2. Take care not to damage the LCD display.
3. Never apply force with the torque wrench when the power is off. Always
turn the unit on before using it.
4. For assured accuracy of the wrench, periodic self re-setting is necessary as
described under MAINTENANCE & CALIBRATION.
5. Check that the wrench operating range is adequate for the anticipated
load before proceeding. Do not exceed the maximum rating of the
wrench (30Nm or equivalent units).