Zanussi ZOU 332 FTI Livret d'instructions - Page 24
Parcourez en ligne ou téléchargez le pdf Livret d'instructions pour {nom_de_la_catégorie} Zanussi ZOU 332 FTI. Zanussi ZOU 332 FTI 28 pages. Built-under oven with gas hob
Adaptation to different types of gas
Injector replacement
•
Remove the pan supports.
•
Remove the burner's caps and crowns.
•
With a socket spanner 7 unscrew and
remove the injectors (Fig. 24), and replace
them with the ones required for the type
of gas in use (see the table below).
•
Reassemble the parts, following the same
procedure backwards.
•
Replace the rating label (placed near the
gas supply pipe) with the relevant one for
the new type of gas supply. You can find
this label in the package of the injectors
supplied with the appliance.
Should the feeding gas pressure be different
or variable compared with the required
pressure, an appropriate pressure adjuster
must be fitted on the gas supply pipe, in
compliance with the rules in force.
Gas
Burner
Type
Natural
Auxiliary
gas
Semi-rapid
G20
Rapid
Liquid
Auxiliary
gas
Semi-rapid
G30/G31
Rapid
Injector
Nominal
1/100
Power
mm
Rate
(kW)
70
1,0
96
2,0
119
3,0
50
1,0
71
2,0
86
2,8
FO 0392
Nominal
Minimum By-Pass Feeding
Flow Rate
Power
in
Rate
(Kw)
m³/h
g/h
0,095
-
0,33
0,190
-
0,45
0,286
-
0,65
-
72
0,33
-
144
0,45
-
202
0,65
Fig. 24
1/100
pressure
(mbar)
adjustable
20
28
32
30
40
49