Electrical connection

Any electrical work required to install this appliance
should be carried out by a qualified electrician or
competent person.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
The manufacturer declines any liability should
this safety measure not be observed.
Before switching on, make sure the electricity supply
voltage is the same as that indicated on the appliance's
rating plate. The rating plate is located at the top of the
rim of the open door.
The appliance is supplied with a 13amp plug fitted.
In the event of having to change the fuse in the plug
supplied, a 13amp ASTA approved (BS1363/A) fuse
must be used.
Should the plug need to be replaced for any reason,
proceed as described below.
The wires in the mains lead are coloured in accordance
with the following code:
Green and Yellow
Blue
Brown
The wire coloured green and yellow must be connected
to the terminal marked with the letter «E» or by the
earth symbol
or coloured green and yellow.
- Earth
- Neutral
- Live
The wire coloured blue must be connected to the
terminal marked «N» or coloured black.
The wire coloured brown must be connected to the
terminal marked «L» or coloured red.
Upon completion there must be no cut, or stray strands
of wire present and the cord clamp must be secure over
the outer sheath.
WARNING:
A cut off plug inserted into a 13 amp socket is
a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely.
The power supply cable must be easily accessible
after installing the appliance.
Permanent connection
In the case of permanent connection it is necessary that
you install a double pole switch between the appliance
and the electricity supply (mains), with a minimum gap
of 3mm between the switch contacts and of a type
suitable for the required load in compliance with the
current electrical regulations.
The switch must not break the yellow and green earth
cable at any point.
26 26