Bitwriter - Only Options
If programming with the Bitwriter®, the learn routine can be locked or unlocked. If the learn routine has previously been locked, it must
be unlocked with Bitwriter® - this cannot be done manually with the control center button.
The Bitwriter®
gives you access to a wider range of system options. These features and the adjustments that may be programmed are
described in the table below.
Menu
Feature
Item
1
Siren Duration
2
Aux 2 Timed Output
3
Aux 3 Timed Output
4
Aux 4 Timed Output
5
Engine Runtime
6
Diesel Start Delay
7
Timer Mode Runtime
8
Virtual Tach Fine Tune
9
Transmitter Programming
10
Feature Programming
Note: The "Zap" feature on the Bitwriter does not reset the Virtual tach or security features enabled/disabled settings
Bitwriter feature descriptions
1.
Siren duration:
Sets the siren output for full trigger activations from 1-180 seconds.
2.
Aux 2 timed output:
Sets the output duration in 1 second intervals up to 90 seconds.
3.
Aux 3 timed output:
Sets the output duration in 1 second intervals up to 90 seconds.
4.
Aux 4 timed output:
Sets the output duration in 1 second intervals up to 90 seconds.
5.
Engine runtime:
Sets engine runtime during normal remote start operations from 1-60 minutes.
6.
Diesel start delay:
Sets the delay before engine crank in 1 second intervals from 1- 90 seconds for diesel engine vehicles.
7.
Timer mode runtime:
Sets the duration of runtime when the engine is started by the Timer Mode from 1-16 minutes.
8.
Virtual tach fine tune:
Adds or subtracts crank time in VirtualTach mode in order to overcome engine types that short crank or over-crank on the first start attempt.
9.
Transmitter programming:
Locks and unlocks the user's ability to enter the remote control/Reset menu and manually change any functions using the Control Center
10. Feature Programming:
Locks and unlocks the user's ability to enter the feature menus and manually change the main unit programming using the Control Center.
16
Default
30 sec.
30 sec.
30 sec.
30 sec.
12 min.
15 sec.
12 min.
Not initialized
Unlocked
Unlocked
Options
1-180 sec.
1-90 sec.
1-90 sec.
1-90 sec.
1-60 min.
1-90 sec.
1-16 min.
0-1000 in 50 millisecond increments
Locked
Locked
© 2012 Directed. All rights reserved.