STARTING THE COMPRESSOR
1. At the beginning of the day, open the drain cock and allow any
condensate to drain completely, then close the drain cock.
2. To ease starting, ensure there is
no pressure in the pump outlet
manifold by opening the Bleed
valve.
3. Connect the air hose to the air
outlet.
4. Connect your air tool to the air
hose.
• Make sure that the air outlet
tap is closed
5. Start the engine in accordance with the instructions contained in the
engine service manual, If this is the first time you are using the compressor,
allow it to run for 10 minutes.
6. Close the bleed valve fully.
• Pressure will build up in the receiver and eventually the air governor will
operate so that the engine runs off load.
• The pressure registered on the pressure guage should be 100psi.
7. Use your air tool as prescribed in its user guide.
• When the pressure has dropped by approximatley 20psi the compressor
will start up again.