1. The limiter valve and the electrical system
can take the appliance load (see the rating
plate)
2. The supply system is equipped with an
efficient earth connection in compliance
with the current standards and regulations
3. The outlet or omnipolar switch used for
connection is easily accessible with the
appliance installed.
The appliance is supplied with a 3 core flexible
power cable with a 3 amp plug. If it is necessary
to change the fuse, use a 3 amp ASTA-
approved (BS 1362) fuse.
A
E
A. Green and Yellow
B. 3 amp fuse
C. Brown
D. Cord clamp
E. Blue
The wires in the cord are coloured as follows:
Green and yellow
Blue
Brown
WARNING!
A cut off plug inserted into a 13 amp
socket is a serious shock hazard.
Ensure that the cut off plug is
disposed of safely.
www.zanussi.com
B
C
D
- Earth
- Neutral
- Live
Replacement of the connection cable
The replacement of electric cable
must be carried out exclusively by
the service force centre or by
personnel with similar
competencies, in accordance with
the current regulations.
To replace the connection cable use
only H03V2V2-F T90 or equivalent
type. Make sure that the cable
section is applicable to the voltage
load and the working temperature.
The yellow/green earth wire (B)
must be approximately 2 cm longer
than the live and neutral wire (A).
1. Connect the green and yellow (earth) wire
to the terminal which is marked with the
letter 'E', or the earth symbol
coloured green and yellow.
2. Connect the blue (neutral) wire to the
terminal which is marked with the letter 'N'
or coloured blue.
3. Connect the brown (live) wire to the
terminal which is marked with the letter 'L'. It
must always be connected to the network
phase. There must be no cut or stray
strands of wire present. The cord clamp
must be correctly attached to the outer
sheath.