Zanussi GAS COOKER ZCG 641 Livret d'instructions - Page 14
Parcourez en ligne ou téléchargez le pdf Livret d'instructions pour {nom_de_la_catégorie} Zanussi GAS COOKER ZCG 641. Zanussi GAS COOKER ZCG 641 20 pages. Zanussi cooktop user manual
Instructions for the Installer
Technical Data
Appliance Class 2 sub class 1 and Class 1
APPLIANCE CATEGORY:
APPLIANCE GAS SUPPLY: Natural Gas G20 20mbar
Dimensions
Height
Depth
Width
Oven Capacity
TYPE OF
CHARACTERISTICS
GAS
NATURAL
VALUE =
GAS
Hs 37.78 MJ/m
3
20 mbar
Ws 50.72 MJ/ m
3
LPG GAS
VALUE =
28-30/37
Hs 49.92 MJ/Kg
mbar
Ws 82.09 MJ/ m
3
Important Safety Requirements
This appliance must be installed in accordance with
the Gas Safety (Installation and Use) Regulations
(current addition) and the I.E.E. Wiring Regulations.
Detailed recommendations are contained in the
following British Standard Codes of Practice - B.S. 6172,
B.S. 5440: Part 2 and B.S. 6891: Current Editions.
For appliances installed in the Republic of Ireland please
refer to NSAI- Domestic Gas Installation I.S. 813
Current Editions and the ETCI Rules for Electrical
Installations.
Provision for Ventilation
The room containing the cooker should have an air
supply in accordance with B.S. 5440: Part 2: Current
Editions.
The following requirements for ventilation must be
met.
14
II2H3+
900 mm
600 mm
600 mm
56 litres / 1.97 Cu. ft
BURNER
POSITION
MAX
NOMINAL THERMAL
POWER (kW)
3.0
NOMINAL FLOW
RATE (m
3
/h)
0.286
NOZZLE REFERENCE
119
1/100 mm
NOMINAL THERMAL
POWER (kW)
2.8
NOMINAL FLOW
RATE (g/h)
202
NOZZLE REFERENCE
86
1/100 mm
Hob
Rear left burner (semi-rapid)
Front left burner (rapid)
Rear right burner (semi-rapid)
Front right burner (auxiliary)
Oven
Electric Grill
Gas Oven burner
Oven light
Total Electric Rating
Supply voltage (50 Hz)
RAPID
SEMI-RAPID
(large)
(medium)
MIN
MAX
MIN
0.65
2.0
0.45
0.062 0.190
0.043
Adjust.
96
Adjust.
0.65
2.0
0.45
47
144
32
40
71
32
The cooker should not be installed in a bed sitting room
with a volume of less than 20m
of volume less 5m
is required; if it is installed in a room of volume between
5m
and 10m
3
required, while if the volume exceeds 11m
required. However, if the room has a door which opens
directly to the outside, no air vent is required even when
the volume is between 5m
If there are other fuel burning appliances in the same
room, B.S. 5440: Part. 2: Current Editions should be
consulted to determine the requisite air vent
requirements.
For appliances installed in the Republic of Ireland
please refer to the NSAI- Domestic Gas Installation I.S.
813 Current Editions Table Four.
AUXILIARY
OVEN
(small)
MAX
MIN
MAX
1.0
0.33
2.7
0.095
0.031
0.257
0.095
70
Adjust.
114
Adjust.
1.0
0.33
2.7
72
24
195
50
28
83
, if it is installed in a room
3
an air vent of effective area of 110cm
3
, an air vent of effective area 50cm
3
and 11m
.
3
3
2000 W
3000 W
2000 W
1000 W
1650 W
2700 W
25 W
1675 W
230 V
MIN
1.0
1.0
72
52
2
is
2
3
no air vent is