Zanussi MI 85.52 LT Manuel d'instruction - Page 18
Parcourez en ligne ou téléchargez le pdf Manuel d'instruction pour {nom_de_la_catégorie} Zanussi MI 85.52 LT. Zanussi MI 85.52 LT 21 pages.
Gas connection
Your cooker is delivered adjusted for the
kind of gas stated on the rating plate.
It might be necessary to pass to another
kind of gas, different to the one it is preset
to. Under these circumstances follow the
instructions bellow.
For
best
consumption and a longer length of life of
your cooker, the manifold gas pressure has
to respect the values shown in table no. 1
If the appliance is supplied with Butane or
Propane gas check that from the pressure
regulator, the pressure for Butane is 28
mbar and for Propane 37 mbar.
1. For cylinder butane propane gas:
•
We advise you to use flexible pipe
according to the national rule in force of
minimum 1 m; this length is chosen
depending on the position of the
connection to the gas supply;
•
For the old butane installations you can
use a flexible rubber pipe of max 1,5 m
and 6 mm diameter, mounted with the
special butane holder ;
•
Fix it well by means of a collar for each
end.
For buying the pipe
•
Flexible rubber hose: it has to be
marked NF GAS
•
Flexible pipe: according to standard NF
D 36 121, or NF D 103, or NF D 36 107
Electrical connection
Important
In any connection way the appliance
has to be grounded, in accordance with
the national rules in force and with
standard NFC 15 100. We decline any
responsibility in case of accidents due to
no grounding or wrong grounding.
efficiency,
lowest
Fitting
Holder
butane
Flexible
rubber
Necklace
41