3.
After the first 100 hours use, replace
the oil completely using Clarke SAE
40 compressor oil.
Thereafter, replace the oil com-
pletely after every 500 hours of
operation or every 6 months.
To empty the oil from the machine,
turn the screw located at the bottom
of the plastic end cover, and shown
at 'B' fig. 6, to the unlocked position,
denoted by the symblol
Ensure the screw is turned back to
the locked position when completed
4.
Every 500 hours of operation or every
6 months
• clean all the external parts of the compressor.
(This cleaning makes the cooling process more efficient and prolongs the life of
the machine).
• Examine the non-return valve and
renew parts if necessary (fig. 7)
(Ref: item 13, page 12 or item 8, page
13)
5.
In the event of an air leak follow the
procedure below:
• Load compressor to maximum pressure
• Unplug the compressor
• With a brush and soapy water wet all 'screwed' air connections
• Any leaks will show through the formation of air bubbles.
NEVER UNSCREW A CONNECTION WHILST THE AIR RECEIVER IS UNDER PRESSURE.
ALWAYS MAKE CERTAIN THAT THE TANK HAS FIRST BEEN EMPTIED.
.