Aleko AC1400 Manuel de l'utilisateur - Page 12

Parcourez en ligne ou téléchargez le pdf Manuel de l'utilisateur pour {nom_de_la_catégorie} Aleko AC1400. Aleko AC1400 16 pages. Sliding gate operator

Aleko AC1400 Manuel de l'utilisateur
AC1400 SLIDING GATE OPERATOR
To erase all existing remote controls, press and hold 'AN' button about 14 sec until the
beeper stops ringing. This indicates that all the remote controls have been erased
completely.
The remote control works in a single channel mode. It has four buttons. The function of
button 1, button 2 and button3 are the same. With each press of the remote control
button which has been programmed, the gate will open, stop, close or stop cycle.
Button 1, button 2 and button 3 are used to open or close the gate. Button 4 is available
to set pedestrian mode. Note: if you canceled the pedestrian mode, the function of button
4 is same as the other three buttons.
Warning: Notify the users that the gate is never to be operated unless it is in full view.
Verify open direction: If the gate does not move in the desired direction, then you will
need to reverse the motor operating direction. You can do this by exchanging wires 'V'
and 'W', 'OP' and 'CL', then insert the wire connector terminal block.
Position
Dip Switch
ON
1
OFF
ON
2
OFF
ON
3
OFF
Set auto-close function (This feature can be selected to make the gate stay open for
some time before it automatically closes. The auto-close time can be adjusted to
between 0 and 44 seconds.): please turn on the first and the second DIP switch (See
Fig.7 No.18) to ON position. Press the remote control button (button 1, button 2 or button
3) that has been programmed to open the gate (see Verify open direction section).
Stop the gate at any position by pressing the same button, wait for some seconds
according to your requirements (the range is 1~44 sec.), this period of time is regarded
as 'auto-close time'. Close the gate by pressing the same button. Press the button again
to stop the gate or the gate will stop automatically at its closed position if the magnetic
limit switch is reached. After this setup is complete, return DIP switch 1 to OFF position
immediately. Thus the auto-close function has been set.
Cancel auto-close function: Please turn on the first and the second DIP switch (See Fig.7
No.18) to ON position. Press the remote control button (button 1, button 2 or button 3)
that has been programmed to open the gate (see Verify open direction section). Stop
the gate at any position by pressing the same button, wait until the gate close
automatically (45 sec.). Press the same button to stop the gate or the gate will stop
automatically at its closed position if the magnetic limit switch is reached. After this setup
Table3 DIP switch
(See Fig.7 No.18)
Function
Programming / In this position the control board is in
programming condition, NOT USE condition.
Normal / In this position the control board can be
normally used.
Auto-close function and auto-close function of
pedestrian mode are available.
Both Auto-close function and auto-close function of
pedestrian mode are shut off.
Limit switch mode is NC.
Limit switch mode is NO.
11