This pump is ONLY for use with the following:
Clean water or water with small solids in suspension (dirty water).
Diesel fuel
Paraffin
DO NOT use this pump for pumping:
Slurry
Sceptic Tanks
Sandy water
WARNING: DO NOT USE FOR PUMPING PETROL
ALWAYS disconnect the pump from the power supply before performing any
maintenance operations.
ALWAYS check the power input cable before use to ensure it is perfectly serviceable.
ALWAYS ensure the filter is clean and perfectly serviceable before use.
NEVER run the pump dry. Minimum water depth is 30mm
DO NOT exceed the duty cycle - see Specifications.
DO NOT use if any part appears to be damaged. Have it repaired by your Clarke dealer.
DO NOT use the pump for any purpose other than that for which it is intended.
DO NOT operate the pump continuously - eg. in a fish pond or collection tank, water
feature etc.
DO NOT use or leave the pump in freezing conditions.
DO NOT allow uncontrolled discharge of contaminated water etc. ALWAYS collect in
a container and dispose of according to all H & S regulations and local laws.
Limitations of Use
Safety Precautions
Specifications
Flow Rate ..................................................... 16.5 litres/min
Min. Water Depth ...................................... 30mm
Voltage ........................................................ 12V
Current ......................................................... 4.5A DC
Pressure ........................................................ 15psi / 1 bar
Height .......................................................... 145mm
Diameter ...................................................... 53.5mm
Weight .......................................................... 0.6kg
Duty cycle ................................................... 15mins continuous in any
30 min period