Clarke CM1 Instructions d'utilisation et d'entretien - Page 9

Parcourez en ligne ou téléchargez le pdf Instructions d'utilisation et d'entretien pour {nom_de_la_catégorie} Clarke CM1. Clarke CM1 15 pages. Engine driven water pump

MAINTENANCE

DAILY, before use.
Check for any loose bolts/screws, or leaking fuel and rectify before proceeding.
Ensure there is sufficient fuel in the tank.
MONTHLY or every 20 Hours
Clean the Air Filter as follows:
Remove centre screw and pull off the air filter cover.
Remove sponge filter and wash in warm soapy water. Rinse thoroughly and allow
to dry before reassembling.
6 MONTHLY or every 50 hours
Ensure the engine is cold before performing the following tasks.
1.
Clean and adjust the Spark Plug:
Pull off the spark plug lead and, using the socket wrench supplied, unscrew
and remove the spark plug.
Clean using a wire brush. When all carbon has been removed, adjust the gap
to 0.6 - 0.7mm, using an appropriate gauge, available from all tool retailers.
2.
Clean the Fuel Filter:
Remove the fuel filler cap completely, then, using
a piece of wire with a hooked end, pull out the fuel
filter and hose, as shown in Fig.6.
Clean the filter thoroughly using clean petrol. If it is badly
contaminated, renew it.
Before reinstalling the filter, clean out the fuel tank,
ensuring there is no sediment collecting in the bottom.
STORAGE:
Should the pump be stored for any period, you should proceed as follows:
Once the engine has cooled, disconnect all hoses and remove the pump drain
plug, Drain the pump completely, and, importantly, flush with CLEAN water
thoroughly, then replace the drain plug.
Drain the fuel tank completely, then, start the engine in the normal manner and
allow it to run until it stops due to lack of fuel.
NOTE: If prolonged storage is probable, fuel could congeal, causing the
components to 'gum up', which would be very problematic.
Remove the spark plug and pour in a teaspoonful of engine oil, then, gently pull
the recoil starter a few times so that the oil is deposited on the cylinder walls,
before replacing the spark plug.
Store the pump, preferably under cover, not exposed to the elements, and in a
clean dry environment.
9
Fig.6