This pump must NOT be run continuously,
TROUBLE SHOOTING
A
PUMP WILL NOT START
1.
Check to ensure power is switched ON.
2.
Check fuse.
3.
Internal Thermal Cut-out has activated. Wait for 20 mins and try again.
4.
Water level too low - float switch in OFF position - Lift float to check switch.
B. PUMP WILL START BUT NOT PUMP
1.
Check to ensure water intake holes, at the base of the pump, are not blocked.
2.
Discharge tube clogged or obstructed.
3.
The head may be too great, i.e. you are trying to lift the water too great a
distance for the pump to cope with. (See specification chart page 7).
4.
Impeller may be damaged - Consult your CLARKE dealer
C. PUMP WILL NOT STOP
1.
Float switch may be prevented from moving to the fully down position.
2.
Float switch may be faulty. Consult your CLARKE dealer for advice.
D. PUMP STOPS RUNNING
1.
Thermal overload has operated. If this condition persists, investigate the cause.
REMEMBER: DO NOT attempt to pump anything other than CLEAN water.
2.
Float switch has cut in.
3.
A foreign object has jammed the impeller.
WARNING
see Duty Cycle - Specifications
6