WASTE PLUMBING
5
Attach P-Trap Enclosure Cover to Basin Assembly using
1/4 - 20 UNC x 3/4" Screws (Provided).
2
1
Basin
2
Grid Strainer w/ 1-1/2 " -16 UNE Threads
3
Rubber Gasket
4
Flat Fiber Washer
1-1/2 " -16 UNI Rough Chrome Brass Jam Nut
5
6
1-1/2 " Tailpiece
Assemble Waste Piping connections and attach 1-1/2" P-Trap to
7
Waste Piping.
Part #: 5914-000-001
1
5
C
4
DETAIL C
1
3
2
TOLL FREE 800-743-8259 • LOCAL 626-855-4866 • FAX 626-855-4863
INSTALLATION, OPERATION
& MAINTENANCE MANUAL
IMPORTANT: To open P-Trap Enclosure and access
components located within, remove upper and front
screws
3
Cover is hinged and will swing down when supported
with the lower mounting screw
1
Basin Assembly
2
P-Trap Enclosure Cover
3
1/4 - 20 UNC x 3/4" Screws (Provided); Hinge Point
4
1/4 - 20 UNC x 3/4" Screws (Provided)
5
#10-32 Captive Nuts (Provided)
Install Grid Strainer and 1-1/2" Tailpiece to Deck using Plumber's
6
Putty.
2
3
5
HINT: Teflon tape is recommended on all
threaded waste and supply connections.
1
Basin Assembly
2
1-1/2 " P-Trap
3
1-1/2 " Tailpiece
Page 8 of 11
4
while supporting the front of the cover.
only.
3
4
6
NEO-METRO FIELD SERVICE
Date: 04/12/21
1