9. Install Hand Guard (32) onto the Housing.
10. Screw the Cap into the Housing.
• Tighten the Cap to 35 ft. lbs. (47 Nm).
Register Assembly
11. Install Register Assembly (20) onto the Housing
• Make sure the Register seats on the four pins.
12. Install Screws (21) that secure the Register Assembly
to the Housing.
• Tighten the Screws securely.
13. Install Setscrew (12) [with Loctite 222] into the Worm
Gear.
14. Install Worm Gear (13) [spur gear upward] onto the
shaft of the Spindle and Gear Assembly.
• Make sure the Worm Gear's setscrew points toward
the flat on the Spindle and Gear Assembly.
• Check to ensure the gear meshes properly with the
Register's gear.
15. Install Washer (22) onto the bottom post of the
Register Assembly.
16. Install Pointer Gear (23) [flat surface downward] onto
the Washer.
IMPORTANT: Make sure the Gears mesh
evenly.
17. Move the Worm Gear [straight upward or downward]
as required so its gear wheel meshes evenly with the
Pointer Gear.
• Tighten the Setscrew securely.
Lock Pawl
18. Install and seat Spring (16) [flat portion first] onto the
the post on the Housing.
• Make sure the Spring seats in the notch.
19. Install Lock Pawl (14) onto the Housing's post.
• Make sure the Lock Pawl properly engages the
Spring.
20. Install Retaining Ring (15) that secures the Lock Pawl
to the post.
Item No.
4
O-Ring
9
Washer
10
O-Ring
33
O-Ring
36
Quad-Ring
Table 2
Components Lubricated in Clean Oil
5
SER 3690-C
Description
Revision (10-04)