Parcourez en ligne ou téléchargez le pdf Manuel pour {nom_de_la_catégorie} Alemite 3575-B. Alemite 3575-B 8 pages. Oil control handle with mechanical meter

Mechanical Meter Oil Control Handle
Notice
!
Do not strike oil control handle
if it fails to operate. Refer to trouble-
shooting guide or return unit to nearest
authorized service center.
Before each use check all hoses for
signs of wear, leaks or loose fittings.
Tighten all fluid connections regularly
and replace weak or damaged hoses.
Before attempting any repairs or
maintenance of product disconnect air
supply from oil pump, release oil line
pressure by pressing lever on oil control
handle.
Assembly
Use Teflon tape (or suitable thread sealant)
when connecting the oil control handle to an
oil hose.
Outlet Nozzle
The outlet nozzle can be fitted either "in
line" (forward) or on the outlet port "pistol
style" located under the handle.
The long outlet tube should be used for the
"in line" option.
The short adaptor (44) should be used with
the outlet nozzle assembly (50) taken off the
long outlet tube when using the "pistol style"
option (see fig. 2).
Notice
!
Use threaded plug supplied to
seal outlet port not in use.
Outlet Nozzle Operation
When fluid flows through the handle the
outlet nozzle will automatically open. When
the fluid flow stops the outlet nozzle will auto-
matically shut.
Initial Release 10-15
50
44
Figure 2
Control meter showing three alternate
pistol-style configurations
2

Operation

To latch the handle first press the lever (40)
followed by push button (37). To release latch
simply press and release lever (40).
The top accumulative register will record
the total volume of oil passed through the me-
ter. The bottom register is a reset-able batch to-
tal, which can be reset by pressing the reset
button.
42

Maintenance

C a u t i o n
Do not perform maintenance with air
supply connected.
Do not perform maintenance with fluid
inside handle under pressure.
Failure to comply may result in minor or
moderate injury.
Inspect your oil control handle daily for any
signs of damage.
Replace any damaged parts or components as
required.
Control Handle
Disassembly
Use a clean bench to carry out maintenance.
1 Remove the oil hose from the control handle
inlet swivel (33).
2 Unscrew and remove swivel (33) washer
(32) and O-ring (31) from the control han-
dle inlet. Clean or replace the strainer (35)
and O-ring (34).
3 Slide off the handle sleeve (27).
4 Remove valve spring (30), valve seal as-
sembly (29) and plunger (28).
Alemite, LLC
SER 3575A