CHARGING PROGRAMS
Settings are made by pressing the MODE-button. After about two seconds the charger
activates the selected program. The selected program will be restarted next time the
charger is connected.
The table explains the different Charging Programs:
Battery
Program
Size (Ah)
Normal battery program
14–225Ah
14.4V/7A. Use for WET batteries,
NORMAL
Ca/Ca, MF and for most GEL batteries
AGM
AGM battery program 14.7V/7A
Use for AGM batteries.
14–225Ah
Recond program 15.8V/1.5A
Use to return energy to the empty
WET and Ca/Ca batteries. Recond
your battery once per year and after
deep dischare to maximise lifetime and
capacity. The Recond program adds the
14–225Ah
RECOND
Recond step to the normal battery
program. Frequent use of the Recond
program may cause water loss in the
batteries and reduce service life of
electronics. Contact your vehicle and
battery supplier for advice.
Supply program 13.6V/7A
Use as 12V power supply or use for
float maintenance charging when 100%
14–225Ah
capacity of the battery is required.
Supply program activates Float step
without time or voltage limitation.
WARNING!
The spark protection on the battery charger
is disabled during SUPPLY program.
4 • EN
20015462E MXS 7.0, Manual EU, Print file 002.indd 4
Explanation
Temp range
+5°C–+50°C
(41ºF–122ºF)
-20°C–+5°C
(-4ºF–41ºF)
-20°C–+50°C
(-4ºF–122ºF)
-20°C–+50°C
(-4ºF–122ºF)
ERROR LAMP
If the error lamp is lit, check the following:
1. Is the chargers positive lead connected to the
batterys positive pole?
2. Is the charger connected to a 12V battery?
3. The clamps are short circuited?
4. Has charging been interrupted in
Restart the charger by pressing the MODE-button. If charging is
still being interrupted, the battery...
...is seriosly sulphated and may need to be replaced.
...can not accept charge and may need to be replaced.
...can not keep charge and may need to be replaced.
READY TO USE
The table shows the estimated time for empty battery to 80% charge
TIME TO 80% CHARGED
BATTERY SIZE (Ah)
20Ah
50Ah
100Ah
150Ah
or
?
2h
6h
12h
17h
2011-10-11 07:58:02