OPERATION

The Devil range of fan assisted electric heaters are suitable for household
(Devil 6002 & 6003 only) or workshop/factory use. They incorporate a
thermostat which detects the temperature of the room air and controls the
heater to maintain a pre-selected temperature between 0 & 40°C. A
manually reset thermal cutout is provided for safety in the event of
overheating on the 6005, 6009 & 6015 models. The 2kw and 3kw units are
fitted with a self-resetting thermal cutout. The fan motor runs independently
of the thermostat and continues running after the heating element has been
switched off.
With the heater sited on a firm level surface and at a safe distance from
flamable objects (in compliance with all safety precautions), plug the heater
into the mains and set the thermostatic control to the maximum temperature
setting. Switch the heater on to one of the following power settings. Once the
room reaches the required temperature, you should turn the thermostatic
control slowly anti-clockwise until the heater switches off. The heater will now
start and stop automatically to mantain the room temperature.
2 KW HEATERS
The 2kw heater has three settings for 1) fan plus single heating element, 2) fan
plus two heating elements and 3) fan plus all three heating elements. The
other control is a progressive thermostat which is rotated through 270
degrees. A cutout is used to maintain a constant pre-set temperature.
3-position fan speed /
temperature control
3 KW HEATERS
The 3kw heater has three settings for 1) fan only, 2) fan plus single heating
element, 3) fan plus both heating elements. The other control is a progressive
thermostat which is rotated through 270 degrees. A cutout is used to maintain
a constant pre-set temperature.
Thermostatic temperature control