TROUBLESHOOTING

Problem
Excessive dust in the
cabinet.
Uneven blasting
action
Inadequate speed or
inefficient blast.
Static electricity
present
Excessive media
blown into the
surrounding
atmosphere when no
vacuum extract is
being used.
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
Check
No dust extract device
used.
Air vent or overflow
blocked.
Abrasive media worn.
Too much abrasive media in
the cabinet.
Loose airline or loose
connections.
Too much abrasive media in
the cabinet.
Abrasive is damp.
Moisture present inside
cabinet.
Abrasive media worn.
Pressure too low.
Dry weather conditions.
Lid not secure.
Air vent filter missing.
8
Solution
Install dust extract
device.
Clean rear vent and
keep vent away from
any wall.
Replace abrasive media
Remove excessive
media.
Tighten fittings and
ensure airline is secure.
Remove excessive
media.
Renew abrasive or dry
thoroughly before use.
Check airline to ensure it
is free from moisture.
Replace abrasive media
Increase inlet pressure
and ensure control valve
is fully open.
Leave the item to be
cleaned on the grid.
Secure the lid with the
swivel clips and adjust
them if necessary.
Replace filter or blank off
hole in rear panel
temporarily with masking
tape.