right side of the unit, remove the cap and put it either in a bucket or barrel and turn the
hose end valve on. Second, open the yellow valve handle on the main shelf. Third,
move the handle back and forth on the sump pump located on the shelf. Pump the sump
out till the solvent changes color. This usually takes 2-5 gallons. Turn off hose end
valve, yellow handle valve, replace cap and return it to its hangar. Dispose of waste
properly.
B.

Canister Lid O-Ring Maintenance

Every time the filters are changed, smear a small amount of petroleum jelly around the
o-ring to keep it lubricated.
WARNING! ALWAYS WEAR GLOVES AND EYE PROTECTION WHEN
HANDLING SOLVENT OR FILTERS.
WARNING! When changing filters, make sure to have something underneath the
used filter as you move it, such as a bucket or oilsorb, to capture any incidental
drips.
C.

Changing Filters.

The PCS-25/WCS-25/PCS-15 comes equipped with one or two 5" X 18" filter canisters.
Inside these canisters are 4.5" X 17" filter cartridges. These filters need to be changed
when indicated by the filter status lights or by a 40 PSI reading on the pressure gauge
mounted on the filter canisters. When the gauge or lights indicate a filter change is
needed please follow these steps:
1. Turn all power to the system off.
2. Unplug the unit from wall receptacle.
3. Remove any soak tanks or supplies located on the working surface.
4. To create access to the filter canister lids for the PCS-25/WCS-25 and PCS-15 lift
and remove cutout located on left side of work surface. With the filter wrench provided,
carefully spin off filter canister.
4. With the lid off, carefully pull the used filter out of the canister. Rest the used filter
on the working tray to allow it to fully drain.
5. Place a new (Clarus Stock# WP680SR) filter in the canister.
6. Once the filter is installed, replace lid, screw it in until it seals, no need to tighten
hard.
7. Return lid wrench to its proper location and replace the tray cutouts etc.
D.

Replacement Parts.