AM Series Thermal Insulation Replacement Instruction
Replacing Burner's Thermal Insulation – Continued
7.
Assembly the ignition and detection electrodes, paying attention to the correct position
of the red gasket (shown with arrows in Figure 16).
8.
Screw the electrodes in place (see Figure 17).
Figure 16: Reassemble the Electrodes
9.
Before reinstalling the burner, clean the surface on which the gasket will sit (shown with
arrows in Figure 18) to ensure a good seal.
10.
Install the reassembled fan burner assembly (see Figure 19) in the heat
exchanger by performing the steps in section 4 – Removing the Burner in reverse
order.
Figure 18: Clean Gasket Surfaces
11.
Complete the instructions above on the remaining burners in the unit.
07/28/2014
AERCO International, Inc. • 100 Oritani Dr. • Blauvelt, New York 10913 • Phone: 800-526-0288
Kit # 62632006
Figure 17: Tighten the Electrodes
Figure 19: Reassemble Burner Assembly
TID-0120_0A