MAINTENANCE & CLEANING
Warning - Failure to carry out routine maintenance leaving the
pump under reduced or no flow conditions for long periods
(i.e. blocked pre-filter) will result in a shorter pump life and
will invalidate the guarantee.
Blagdon Minipond 2000
movement driven by a watertight synchronous motor. They require minimum
cleaning, only periodic cleaning of the pre-filter and impeller is necessary.
Routine Maintenance
Carry out routine maintenance when pump flow is visibly reduced.
1.
Switch off electricity.
2.
Remove pump from pond (do not use the cable to lift the pump).
3.
Remove the front of the pre-filter cage by depressing the button and pulling
apart. Wash the cage thoroughly in fresh water. A blocked pre-filter will
reduce pump flow. Follow steps 1 and 2.
STEP 1:
MINIPOND 2000 (ROUTINE)
Firmly pull pre-filter cage from pump
motor.
DEPRESS BUTTON
is a centrifugal pump with a magnetic impeller
STEP 2:
MINIPOND 2000 (ROUTINE)
Remove pre-filter foam (if fitted), and
wash thoroughly in fresh water. The
pre-filter is for use with Daisy Jets only.
A blocked foam will reduce the pump
flow rate.