DISCOVER 12-36-6700 Manuel d'utilisation

2. Battery Operating Limits

2.1 Maximum Battery Operating Limits

The battery should not be operated outside the Maximum Operating Limits, the BMS will open its internal relay and disconnect
the battery if any of the following limits are exceeded.
Maximum Operating Limits
Continuous Charge Current*
Continuous Discharge Current*
Operating Voltage (Min / Max)
Charge Temperature (Min / Max)
Discharge Temperature (Min / Max)
Storage Temperature (Min / Max)
* Effects of AC Ripple must be taken into consideration when sizing and configuring your system.

2.2 Current Protections

The programmed over current protections of the BMS follow the curves seen in the next two figures:
High Current Interrupt Time (100-150%)
100%
110%
120%
% of Fuse Rating
2.3 Recommended Battery Operating Limits for High AC Ripple Applications
The battery maximum operating limits are specified for DC current and voltage and do not account for AC ripple typically caused
by frequency conversion electronics such as inverter/chargers. The following operating limits are recommended for these types
of systems.
Recommended Operating Settings
Max Continuous Charge Current
Max Continuous Discharge Current
Charge Voltage (Bulk/Absorb)
Charge Voltage (Float)
Low Voltage Disconnect
Operating Temperature
4
Charge Voltage
130%
140%
150%
Intentional bypassing of BMS to operate the battery
outside maximum and minimum limits voids warranty.
14-24-2800
12-36-6700
110 Adc
150 Adc
110 Adc
150 Adc
27.2 V
40.8 V
22.4 V / 29.2 V
33.6 V / 43.8 V
0°C / 45°C (32°F / 113°F)
-20°C / 50°C (-4°F / 122°F)
-20°C / 45°C (-4°F / 113°F)
High Current Interrupt Time (200-600%)
160%
200%
300%
▲ NOTE!
14-24-2800
12-36-6700
< 78 A
< 106 A
< 78 A
< 106 A
27.2 V
40.8 V
26.8 V
40.2 V
24 V
36 V
20°C (68°F)
12-48-6650
130 Adc
130 Adc
54.4 V
44.8 V / 58.4 V
400%
500%
600%
% of Fuse Rating
12-48-6650
< 92 A
< 92 A
54.4 V
53.6 V
48 V
discoverbattery.com
700%