Section 4: System Inspection
Instructions
After the Installation and operational check of the system:
1. Place warning label on the door (as per ANSI A156.10
or A156.19 guidelines). This will advise the person
entering the swing side zone that the door will move.
2. Instruct the owner on door system operation and how to
test it. This should be checked on a daily basis.
3. Instruct the owner on what to do if the door or any of its
components become damaged.
4. Strongly recommend to the owner that the complete
entry be inspected twice a year as part of the service
agreement.
Section 5: Technical Data
No. of IR Sensors
(1)
Batteries (Supplied)
(2) 'AA' Alkaline (Supplied)
2 Years (Based on 100
Estimated Battery Life
Operations/Day)
Standard Operating
1"- 12" (25.4mm - 304mm)
Range
Factory Set to 6" (152 mm)
Momentary
Operating Mode
Momentary with Alarm
'Request to Exit' External
Inputs
(Door Contact) Input
TX-99 Plug-in 915Mhz. Spread Spectrum
Wireless Output
Wireless Transmitter
Relay Output
(1) Form 'C' (SPDT)
Relay Contact Rating
2 Amps @ 30 VDC
Output Type
Fail-secure
Push Buttons
Key Pads
5502 Timberlea Blvd.,
Mississauga, ON Canada
L4W 2T7
Questions? Call us toll-free at 1-877-226-3369
Strikes
Magnetic Locks
www.camdencontrols.com
Toll Free: 1.877.226.3369
Page 4 of 4
1 /
1
38 mm
3
1/4 "
79mm
Diagram 5
Jamb Cutout Dimensions
1"
(25.4mm)
0'
1'
2'
Diagram 6
Adjustable Range Settings
Key Switches
Relays & Timers
2 "
7 / 8 "
2
73mm
Drill & Tap
6-32 (2 holes)
12"
(304mm)
3'
Access Control
File: CM-333 hands-free switches
manual_R2.indd
Revised: 07/03/2018
Part No: 40-82B195