CM-331 & CM-332 Active Infrared "Hands-Free" Switches Installation Instructions
Appendix A – Operating Mode Scenarios
DIP Switches
Scenario
1
2
1
OFF
OFF
2
OFF
OFF
3
OFF
OFF
4
OFF
OFF
DIP Switches
Scenario
1
2
5
ON
OFF
6
ON
OFF
7
ON
OFF
8
ON
OFF
Motion
Sensing
3
4
Mode
OFF
OFF
ON
OFF
Mom
OFF
ON
ON
ON
Motion
Sensing
3
4
Mode
OFF
OFF
ON
OFF
Mom/Alarm
OFF
ON
ON
ON
OPR
Relay1 activates as per POT2. If object is kept in front of unit,
Relay1 will operate once and cannot be re-triggered until object
Simple
is removed. When re-triggered while Relay1 is active, Relay1
operation time is reset as per POT2. No alarm is generated if
object is kept in front of unit.
Relay1 activates as per POT2, delay as per POT3, Relay2 activates
after the delay, as per POT4. If object is kept in front of unit,
Relay1 and Relay2 will operate once and cannot be re-triggered
until the object is removed. If unit is re-triggered while Relay1
is on and Relay2 is off, Relay1 operation time is reset. If unit is
Sequence
re-triggered when Relay1 and Relay2 are on, Relay1 and Relay2
operation time is reset and Relay2 will deactivate X seconds after
Relay1 according to the set delay. If unit is re-triggered when
Relay1 is off and Relay2 is on, Relay1 will activate as per POT2
and Relay2 operation time will reset. No alarm generated if object
kept in front of unit.
If door is closed, Relay2 activates, delay begins as per POT3,
Relay1 activates after the delay as per POT2. Relay2 deactivates
only when door is closed. If the door is closed before Relay1
activates, Relay1 will still activate. If the door is already opened
when unit is triggered (due to the unit already being triggered),
Relay2 will already be active and remain active until the door is
closed, Relay1 will activate after the delay. If the door is already
Security*
opened but not because unit was triggered, Relay2 will activate,
delay begins as per POT3, Relay1 will activate after the delay
as per POT2. If object is kept in front of unit, unit will operate
once and will not re-trigger until object is removed. If re-triggered
while Relay1 is active, Relay1 operation time is reset as per POT2.
Alarm is generated if door is sensed open for 30 seconds (this is a
separate alarm, turns off when door is sensed closed).
Relay1 toggles, Relay2 activates as per POT4. Relay2 only
activates when Relay1 is toggled on. If object is kept in front of
Toggle**
unit, Relay1 will stay in the same state and Relay2 will operate
once. Unit cannot be re-triggered until object is removed. No
alarm generated if object kept in front of unit.
OPR
Same as Scenario 1. Alarm generated if object remains in front
Simple
of unit for 30 seconds. Alarm released once object is removed.
Same as Scenario 2. Alarm generated if object remains in front
Sequence
of unit for 30 seconds. Alarm released once object is removed.
Same as Scenario 3. Alarm is generated if door is sensed
open for 30 seconds or if object remains in front of unit for 30
Security*
seconds. Alarm released when door is sensed closed and object
is removed.
Same as Scenario 4. Alarm generated if object remains in front
Toggle**
of unit for 30 seconds. Alarm released once object is removed.
Page 7 of 8
Operation
Operation