Dimensions
GENERAL INSTRUCTIONS FOR INSTALLING
Only skilled, qualified staff must install this product.
Warning! Before working on the control panel, cut off the main current supply and, if present, remove any batteries.

Preliminary checks

Before beginning the installation, do the following:
• make sure you have set up a suitable dual pole cut off device along the power supply that is compliant with the installation
rules. It should completely cut off the power supply according to category III surcharge conditions (that is, with minimum
contact openings of 3 mm);
protection circuit) are fitted with additional insulation with respect to those of other electrical parts inside:
set up suitable tubes and conduits for the electric cables to pass through, making sure they are protected from any mechanical
damage
Cable types and minimum thicknesses
Connection
Control panel power supply 230 V AC
Motor/encoder power supply 24 V DC
Flashing light
Photocell transmitters
Photocell receivers
Command and safety device
Antenna
If cable lengths differ from those specified in the table, establish the cable sections depending on the actual power draw
of the connected devices and according to the provisions of regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, the dimensions on the table need to be recalculated according to the actual
power draw and distances. If connecting products that are not contemplated in this manual, see the literature accompanying
said products
make sure that any connections inside the container (ones that ensure continuity to the
Cable type
FROR CEI
20-22
CEI EN
50267-2-1
RG58
Cable length
Cable length
1 < 10 m
10 < 20 m
2
3G x 1.5 mm
3G x 2.5 mm
2
3 x 1 mm
3 x 1.5 mm
2
2 x 0.5 mm
/
2
2 x 0.5 mm
2 x 0.5 mm
2
4 x 0.5 mm
4 x 0.5 mm
2
2 x 0.5 mm
2 x 0.5 mm
max 10 m
(mm)
Cable length
20 < 30 m
2
2
3G x 4 mm
2
2
3 x 2.5 mm
/
2
2
2 x 0.5 mm
2
2
4 x 0.5 mm
2
2
2 x 0.5 mm