7.2 Trouble shooting
MALFUNCTIONS
POSSIBLE CAUSES
The gate will not open
• There is no power
nor close
• The gearmotor is released
• The transmitter's batteries are run down
• The transmitter is broken
• The stop button is either stuck or broken
• The opening/closing button or the key selector are stuck
The gate opens but
• The photocells are engaged
will not close
The flasher does not
• The bulb is burnt
work
8 Maintenance
Periodic maintenance log for end-user (every 6 moths)
Date
8.1 Extra-ordinary maintenance
The following table serves to note down any extraordinary maintenance, repairs or improvements performed by specialised firms.
N.B.: Any extraordinary maintenance must be performed by specialised technicians.
Extra-ordinary maintenance log
Installer's stamp
Job performed _______________________________________________________________________________________
__________________________________________________________________________________________________
_
Installer's stamp
Job performed _______________________________________________________________________________________
__________________________________________________________________________________________________
_
Notes
Operator name
Date of job
Technician's signature
Requester's signature
Operator name
Date of job
Technician's signature
Requester's signature
CHECK AND REMEDIES
• Check that the power is up
• Call assistance
• Replace batteries
• Call assistance
• Call assistance
• Call assistance
• Check that photocells are clean
and in good working order
• Call assistance
• Call assistance
Signature