6.6 Electrical connections
L1
L2
M
M
N
11
E
+10
-11
1
2
2
3
2
3P
2
7
2
C1
2
C3
2
FC
F
FA
F
FC
10
230V (a.c.) power supply
24V(d.c.) motor
24V output in motion (e.g. fl ashing light 25W)
24V powering accessories max. 40W
Pushbutton stop (N.C.)
Pushbutton open (N.O.)
Pushbutton partial opening (N.O.)
Contact radio and/or pushbutton for controlled (see dip-switch 2-3)
Contact (N.C.) for «re-aperture during closure»
Contact (N.C.) for «partial stop»
(24V-3W max.) gate-opened signal lamp
Connection limit switch opens
Connection limit switch closes
Antenna connection
N.B. Maintain polarity when connecting photoelectric cells (DIR)
10 10 11 11 E1 E1 1 1
2 2
3 3
3P C1
3P
C1 C3
C3 7 7