Connecting to the control panel

For electrical connections, check with the CAME control panel manual.
Check the control panel manual.
1) Control panel
2) Left gear motor
3) Right gearmotor
4) Junction box
5) Junction pit
Electrical connections of the gearmotors to the control panel
U V W X Y E
230 V A.C.
Power supply
Connecting the 230 V A.C. gearmotor with
opening delay
1
4
E3
+
E
-
+
E
-
GREEN
BROWN
WHITE
BLUE
BLACK
BROWN
2
5
BLUE
BROWN
BLACK
Connecting the 230 V A.C. gearmotor with
closing delay
4
3
GREEN
BROWN
WHITE