8 Settings

- END ADJ/SENS.
- AMP SENS.
- SLOWDOWN/AMP SENS
- OP TIME
- ACT
- DELAY 2M
* Warning!: minimum sensitivity = maximum power

Adjusting the closing strike zone

After setting the slowdowns (fi g. 3) with the "micro-switch adjusting" illustrated in the gearmotor manual ...
... prepare a 60 x 30 mm template and keep it rested against one of the two strike plates, as shown in fi g. 1 (you can adjust it either on
the closing or opening strike plates).
Activate the gate - with a command button or with the transmitter - and turn the OP TIME trimmer clockwise until the gatge leaf inverts
its direction of travel the moment it touches the obstacle/template.
Then turn the template from the short side (fi g. 2) and check that the gate lead stops by touching the obstacle/template.Otherwise turn
the trimmer counter-clockwise.
If you have a two-leaf gate, carry out the procedure on both gate leaves.
fi g. 1
OP TIME
* End adjustement of amperometric sensor during travel:min/max.
* Adusts the amperometric sensitivity which controls the force developed by the motor during
movement; if the force exceeds the adjusted level, the system intervenes and inverts the direction of
travel.
* Adusts the amperometric sensitivity which controls the force developed by the motor during
movement; if the force exceeds the adjusted level, the system intervenes and inverts the direction of
travel.
Adjusts the closing strike zone.
Adjusts the waiting time when open.Once this time elapses, automatic closing is triggered.The waiting
time can be adjusted to between 2 and 120 seconds.
Adjusting the M2 waiting time for each closing.The waiting time can be adjusted to between 1 and 15
seconds.
fi g. 3
+
fi g. 2
A = Eff ective zone of the amperometric sensor
with movement inversion
B = Normal speed travel zone
C = Decelerated speed travel zone
D = Eff ective zone of the amperometric sensor
with movement stop
E = Closing and opening strike plates
-
OP TIME