Aeris SmartSense Manuel de débogage - Page 2

Parcourez en ligne ou téléchargez le pdf Manuel de débogage pour {nom_de_la_catégorie} Aeris SmartSense. Aeris SmartSense 4 pages.

Aeris System Debugging Guide
AERIS SmartSense installation debugging guide
1. With the entire system connected apply power. Does the red light D1 on the control box circuit
board blink at power up 3 times?
If no then check power connections +12 and Ground continuity to the circuit board
and the 7 pin connector and verify the ABS harness is firmly plugged in.
2. If all 4 flow lights (D2-D5) on the control box circuit keeps blinking after the power on 3 blink
sequence then the system does not have air pressure yet.
Check that the air control valve is in the on position.
If the control valve is in the on position then the brake system has not received
enough air to open the PPV valve yet. Wait for the airbrake tank to fill or check glad
hands are connected to the tractor.
3. After power up works successfully and the system has Air Pressure, verify that the Front Driver
Warning Light (DWL) blinks three times at each power up.
If the DWL does not blink on power up then check power +12V and Ground
continuity on the terminals to the 7 pin connector and verify that the bullet
connectors are firmly plugged in
4. Once all systems are blinking on a power on event check for a communication connection between
the Control box and the DWL. If communications have not been established yet the LCD on the DWL
should display a "1". Once communications are established the "1" will change to some other
number and the bound Icon (looks like a chain link) will be turned on along with a signal strength
indication. The signal strength indication is continuously updated for about 10 minutes after each
power on event and can be used to discover control box mounting problems.
If the LCD displays a "1" then the system has not established communications with
the control box yet. The system should begin communicating with the control box in
less than 1 minutes on a new install
If the bound icon is lit but the system still displays a "1" error code and this is part of
a recent repair where the control box was replaced then communications will be
reestablished in roughly 2 minutes.
d
August 2015
Page 2 of 4