Alto-Shaam 1000-TH-I/HD Instructions d'installation, d'utilisation et d'entretien - Page 10
Parcourez en ligne ou téléchargez le pdf Instructions d'installation, d'utilisation et d'entretien pour {nom_de_la_catégorie} Alto-Shaam 1000-TH-I/HD. Alto-Shaam 1000-TH-I/HD 16 pages. Low temperature oven cook hold
T
r o u b l e S h o o t i n g
TROUBLE
Unit does not operate.
Cooking temperature not correct.
Holding temperature not correct.
Timer runs down, but oven will not
go into HOLD.
Cook thermostat erratic — will not
hold calibration.
Hold thermostat erratic — will not
hold calibration.
Oven goes from cooking temperature
to cold.
Oven will not go into cook cycle when
timer and cook thermostat are ON.
It takes too long to cook
(temperature O.K.).
Cannot control temperature but
thermostats check O.K.
This section is
provided for the assistance of qualified technicians only and
is not intended for use by untrained or unauthorized service personnel.
Do not replace any electrical components without first
disconnecting electrical power to the unit by switching
A warning sign should be posted on the panel indicating the oven is
being serviced and that the power must remain O
Insufficient electric power unit.
Defective plug or cord.
Power switch defective.
Cook thermostat out of calibration.
Hold thermostat out of calibration.
Timer not de-energizing cook circuit.
Cook thermostat.
Hold thermostat.
Hold thermostat.
Timer or contactor.
Heating element open, resulting in
low wattage.
Heating element grounded.
O
the electrical power at the rear of the oven.
FF
# 8 3 7 A O & C
S E R V I C E
POSSIBLE CAUSE
M A N U A L • 1 0 0 0 - T H - I F A M I L Y
P G . 8
REMEDY
Check power source.
Check and repair if necessary.
Replace.
Calibrate.
Calibrate.
Replace timer.
Replace thermostat.
Replace thermostat.
Replace hold thermostat.
With timer turned ON, line
voltage should appear across
term. 2 and 3 of timer. If not,
replace timer.
If line voltage does appear
across term. 2 and 3 of timer, it
should also appear across
holding coil of contactor.
If line voltage does appear
across holding coil, and it
won't close its contacts,
replace contactor.
Replace element.
Replace element.
.
FF