4.3 Measuring

For optimum results make sure you use a representative oil sample and that
its temperature is not higher than 40 °C (100 °F). Place enough oil in the
sensor to fully cover the sensor surface. Press the test button and keep it
depressed for 10 seconds or until the segments have stopped moving around
the display (the display will flash to show the unit is testing). The result will
remain on the display when the button is released until the next test is carried
out.
To test again, clean out the sensor well with a clean rag or tissue. Refill the
sensor well and press the test button again. A new reading will appear on the
display.

4.4 Interpretation of the reading

Users should use the BALTECH OA-5000 to monitor the change in the oils
properties and build up a picture of oil degradation based on their experience
and own operating criteria.
Individual thresholds of acceptability can be marked on the unit's scale. The
red and green areas are designed as an indicator of the condition of an
engine oil.
Within the green band the oil is deemed acceptable and within the red area
the oil should be changed and checked again after a short running period to
ensure no mechanical problems are present.
Operating instructions
BALTECH OA-5000
Operation manual
9