Bytes
Modbus does not know a byte or character data type (see
address space). Strings or byte arrays are mapped in "hold-
ing registers" (2 characters per register) and transmitted as
a "character stream", e.g. "Hello_World".
Register
HEX
char
40101
Ox4865
‚H' ‚e'
40102
Ox6C6C
‚l'
‚l'
40103
Ox6F5F
‚o' ‚_'
Words
Registers or words are transmitted according to specifi cation
in "Big Endian" format, e.g. Read Holding Register 40101
of Slave 17.
Real
Modbus does not know any data types to represent fl oat-
ing point numbers. On principle, any data structures may
be mapped on the 16Bit register ("cast"). The IEEE 754
standard is the most used standard to represent fl oating
point numbers.
Bit
31
24
23
V
E
E
E
E
E
E
E
E
M
M
M
M
M
Exponent
Algebraic sign
The fi rst register contains Bits 15 – 0 of the 32-bit number
(bit 0...15 of the mantissa).
The second register contains Bits 16 – 32 of the 32-bit number
(algebraic sign, exponent and Bit 16- 22 of the mantissa).
6.3 Mapping
Address space
The address space may be divided into 4 address spaces
according to the 4 types of data.
Space
r/w
Address area
Readable
Coil
00001 - 09999
Writeable
Only reada-
Discrete input
10001 - 19999
ble
Only reada-
Input register
30001 - 39999
ble
Holding
Readable
40001 - 49999
register
Writeable
1)
not implemented
To reduce the commands, the device image was represented
as far as possible in "holding registers".
Segments
Address
Description
40209 - 40210
Actions
40257 - 40284
Measured values, status
40515 - 40516
Settings (Modbus)
40517 - 40761
Confi guration data
41076
Device type
Camille Bauer
Register
HEX
char
40104
0x576F
‚W' ‚o'
40105
0x726C
‚r'
40106
0x6400
‚d'
16 15
8 7
M
M
M M M
M M M M M M M M M M M M M M
Mantissa
Function code
0x01
Read Coil Status
0x05
Force Single Coil
0x0F
Force Multiple Coils
0x02
Read Input Status
0x04
Read Input Register
Read Holding
Registers
0x03
Force Single
0x06
1)
Register
0x10
Preset Multiple
Registers
Permitted function codes
Read Holding Registers
0x03
Preset Multiple Regi-
0x10
sters
0x03
Read Holding Registers
Operating instructions V604s Be
Syntax
Start address of the described data block (register, coil
Address
or input status)
Description
Unique variable or structure description
Data type of variable (U: unsigned, INT: integer, 8/16/32
Data type
bit, REAL or CHAR[..])
Offset from the start address in the data type unit, for
#
Byte 0: Low, 1: High byte
‚l'
Default
Value upon derlivery or after a hardware reset
Exact details concerning the variable described
Description
6.4 Device identifi cation
The device is identifi ed by "Read Slave ID".
Function 11h: Report Slave ID
Master telegram:
Device
Function
address
ADDR
0x11
0
Slave telegram:
Device
Function
Address
ADDR
0x11
Device
Sub-ID
ID
0x01
0x00
0x02
0x00
0x03
0x01
0x04
0x00
0x05
0x00
0x05
0x01
1)
0x05
0x02
1)
1)
0x05
0x03
1)
Device information
1)
Adress
Description
41076
DEVICE
CRC
LO
HI
Number
Slave
Sub
Data
data bytes
ID
ID
2
3
Device
Description
VR660
Temperature controller
A200R
Display
CAM
Universal measuring unit for heavy current
variables
APLUS
Multifunctional display
V604s
Universal transmitter
VB604s
Universal transmitter multi in/out
VC604s
Universal transmitter second Relay
VQ604s
Universal transmitter fast setting time
Data type
Description
UINT16
Device type
Bit
Description
0
Reserved
1
Reserved
2
0: V / mA inputs
1: 2 x mA inputs
3-15
Reserved
CRC
LO
HI
9