The AEC function provides full bandwidth (20Hz to 22kHz) echo filtering of the microphone signal. It uses a reference
source (Dante input 5) which should include a mix of all far end participant receive audio that is being delivered to the
room speakers.
Non-linear Processing (NLP) increases the power of echo cancellation for challenging acoustical environments.
You can select the following:
• Whether or not you want to use AEC. Tap or click the checkbox (a) if you want to use AEC.
• The level of aggressiveness. Tap or click the appropriate radio button (b).
Note: AEC processing is only available for the SmartMix Dante output channel 13 from the BMA 360D.
13