2180 Air Relief Valve Repair Kits
6. Tank pressure should be allowed to rise at a rate of approximately
2 PSI / second. Flow rates greater than this will cause the relief valve
to flutter rapidly. In this condition the valve plate inertia may cause the
apparent opening pressure to be lower than the calibrated value and
will make accurate testing impossible.
7. The relief valve will start to discharge at a pressure slightly below
the rated value, at this pressure some hissing may be evident but the
pressure in the tank should continue to rise (assuming air source
provides a sufficient flow rate). The valve opening pressure (RATED
VALUE) can be read on the tester pressure gauge when the valve
plate (11) reaches an equilibrium (open) position.
8.
If the air supply provides a flow rate in excess of the
maximum flow rate capacity of the relief valve at the relieving
pressure, the valve will not be able to relieve a sufficient volume
of air to prevent tank pressure from continuing to rise. In this
condition serious personal injury and extensive property
damage may occur due to over pressurization of test
components.
Valve Installation
1. Prior to installation, clean any dirt or foreign matter from threading
surfaces.
2. Install air relief valve in positions ranging from vertical (0°) to
horizontal (90°). Do not install valve in inverted position.
3. Install air relief valve with exhaust area positioned so exhaust
vents safely (preferably down as shown in attached diagram). In
horizontal applications, ensure that the small vent hole in the side of
the top cover is facing downward. Downward venting helps prevent
dirt or debris from entering the valve.
4. Apply pipe sealant to threading surfaces prior to installation.
5. Thread the valve into place by hand and tighten using a crescent
wrench (or equivalent) across the hex flats.
2180 AIR RELIEF VALVE RK